From: Bob F <bobnospam@gmail.com>
Newsgroups: sci.electronics.repair
Subject: Re: Altec Lansing ATP3 Speaker system transformer failed.
Date: Mon, 29 Apr 2024 09:43:50 -0700
Organization: A noiseless patient Spider
Lines: 32
Message-ID: <v0oiog$1ro88$1@dont-email.me>
References: <v0mkuj$1abr8$1@dont-email.me>
 <ni1u2j1ag4fajqsrntf59j8dr5pnmn36c4@4ax.com> <v0n5c6$1had0$1@dont-email.me>
 <1qsrre4.7fa29yjqktpkN%liz@poppyrecords.invalid.invalid>
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8; format=flowed
Content-Transfer-Encoding: 7bit
Injection-Date: Mon, 29 Apr 2024 18:44:00 +0200 (CEST)
Injection-Info: dont-email.me; posting-host="e5f70956cb5fb1dc0208151c3b2a5cf3";
	logging-data="1958152"; mail-complaints-to="abuse@eternal-september.org";	posting-account="U2FsdGVkX19ZEX71YNamStVuJyUtBrtF"
User-Agent: Mozilla Thunderbird
Cancel-Lock: sha1:JK8y1FCWkDTox+t7hx2b45pM8eU=
In-Reply-To: <1qsrre4.7fa29yjqktpkN%liz@poppyrecords.invalid.invalid>
Content-Language: en-US
Bytes: 2559

On 4/29/2024 1:28 AM, Liz Tuddenham wrote:
> Bob F <bobnospam@gmail.com> wrote:
> 
> [...]
>> No output. Ohmmeter resistance shows infinite on primary and secondary.
>> 2 leads on primary, 2 on secondary, going to 4 diodes on the circuit board.
> 
> Does it look badly burnt or is there no physical sign of stress?

No sign of either. I just pulled out the circuit board, and no visual 
sign of damage. The diodes and cap on the power input to the board test OK.

> 
> It would be very unlikely that both windings would go O/C simultaneously
> unless it had failed catastrophically and that would be rather obvious
> from the outside.

Kind of weird. It worked one day, but not at all the following morning.

> 
> Simple question:  Did you measure the resistance between the two ends of
> the same winding or are the terminals laid out in a confusing way, so
> you measured resistance between two different windings?

I measured across the wires going toward the power cord for the primary, 
and the wires going to the circuit board for the secondary. 2 pairs of 
wires completely different wires, one pair from each side.

I moved a system that used to be used in my exercise room up, and it fit 
in my space, so no crisis. Maybe I will try unwinding the transformer 
coil some time I'm feeling bored.