Deutsch   English   Français   Italiano  
<v69qak$3f1gb$1@dont-email.me>

View for Bookmarking (what is this?)
Look up another Usenet article

Path: ...!2.eu.feeder.erje.net!3.eu.feeder.erje.net!feeder.erje.net!eternal-september.org!feeder3.eternal-september.org!news.eternal-september.org!.POSTED!not-for-mail
From: "Jim Wilkins" <muratlanne@gmail.com>
Newsgroups: rec.crafts.metalworking
Subject: Re: I Quit
Date: Fri, 5 Jul 2024 17:57:59 -0400
Organization: A noiseless patient Spider
Lines: 29
Message-ID: <v69qak$3f1gb$1@dont-email.me>
References: <v66tt7$2so7t$1@dont-email.me> <v676ka$2udq1$1@dont-email.me> <v67bh1$2v2ot$1@dont-email.me> <v68lrr$395jp$1@dont-email.me> <v69l0s$3e65q$1@dont-email.me>
MIME-Version: 1.0
Content-Type: text/plain;
	format=flowed;
	charset="UTF-8";
	reply-type=response
Content-Transfer-Encoding: 7bit
Injection-Date: Fri, 05 Jul 2024 23:58:45 +0200 (CEST)
Injection-Info: dont-email.me; posting-host="d7724f50f9dda3a4f6b7830e88427116";
	logging-data="3638795"; mail-complaints-to="abuse@eternal-september.org";	posting-account="U2FsdGVkX1+1be7x5ZIxT1MJtdEQofCPfNXll0ZhJ0A="
Cancel-Lock: sha1:tVub1kJxsexcK/ZhYqbSr6ZxxQ8=
X-Antivirus-Status: Clean
X-MSMail-Priority: Normal
Importance: Normal
X-Priority: 3
X-Antivirus: AVG (VPS 240625-0, 6/24/2024), Outbound message
X-Newsreader: Microsoft Windows Live Mail 16.4.3505.912
In-Reply-To: <v69l0s$3e65q$1@dont-email.me>
X-MimeOLE: Produced By Microsoft MimeOLE V16.4.3505.912
Bytes: 2875
X-Original-Lines: 1

"Bob La Londe"  wrote in message news:v69l0s$3e65q$1@dont-email.me...

If I could get all the tiny little losses eliminated I'd be tempted to
use both tanks for air storage, and just periodically switch which
compressor fills them. Then even if a compressor failed it would carry
the air seals for hours.

I also considered some sort of auto backup.  The easy way would be to
set the backup compressor to switch on at a lower pressure, but there
are a number of small issues that could cause both compressors to run at
the same time.  That's power I do not always have.  I never intended to
have a working machine shop.  This was just supposed to be a warehouse
for my contracting business.  I only have a 100 amp sub panel feeding
everything.  I know.  I know.  Upgrade the sub panel.  The house only
has a 200 amp main, and my wife wants to run electric demand heaters.
I'll have to upgrade the house main first.
Bob La Londe

-----------------------------------

I have one of these on my refrigerator as part of a plan to add load sensing 
to a true sine UPS with high idle current draw. It powers itself from the 
current sense coil, whose output lights the red LED and turns on the output 
MOSFET.
https://www.amazon.com/Current-Adjustable-Sensing-Flameproof-Normally/dp/B0CX89X32D

It or a higher rated one could control a contactor that disconnects the 
backup compressor when the main one's motor is drawing current, even if the 
belt is broken.