| Deutsch English Français Italiano |
|
<vva6u9$c2lp$1@dont-email.me> View for Bookmarking (what is this?) Look up another Usenet article |
Path: news.eternal-september.org!eternal-september.org!.POSTED!not-for-mail From: "Tom Del Rosso" <fizzbintuesday@that-google-mail-domain.com> Newsgroups: sci.electronics.design Subject: Re: Cap C-V test Date: Mon, 5 May 2025 07:20:10 -0400 Organization: A noiseless patient Spider Lines: 19 Message-ID: <vva6u9$c2lp$1@dont-email.me> References: <sik71k9uvbqacp964bvlc5317ga12gu9al@4ax.com> Injection-Date: Mon, 05 May 2025 13:20:42 +0200 (CEST) Injection-Info: dont-email.me; posting-host="f92fc8480a4aacc726b7f8dd095a03c0"; logging-data="395961"; mail-complaints-to="abuse@eternal-september.org"; posting-account="U2FsdGVkX1/I587ifcFIeyR6AGy+/VfVYDogzN1vXL4=" Cancel-Lock: sha1:D5XlXtJDT3cz1R9KrG4c38NcqeE= X-RFC2646: Format=Flowed; Original X-MSMail-Priority: Normal X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.6157 X-Newsreader: Microsoft Outlook Express 6.00.2900.5931 X-Priority: 3 john larkin wrote: > https://www.dropbox.com/scl/fi/a7425c69k3w8wx8tqjpq5/X110_CV_Test.jpg?rlkey=pc3c0b12ncswv6ajrn148stdk&raw=1 > > > The DUT is a Venkel 2.2 uF 100v 1812-size ceramic cap. I need to run > it at 48 volts. 0.8 uF is probably OK. I have room on my board so I > guess I'll add another cap in parallel. > > My AADE cap meter was behaving strangely here, so I measured C by > noting the -3 dB frequency driving the cap from a 50 ohm sine wave > generator. Do inductors vary with current as well? I would guess only a little bit. -- Defund the Thought Police