On 06/24/2022 03:30 PM, Gauloisjesuis wrote:

> fait une mesure, actuellement 5°C / 4K7, donc soit c'est la sonde qui 
> est HS soit c'est le processeur.

une NTC qui fait 4k7 à 5°C, c'est une NTC 2K.

donc c'est simple, elle doit faire 2K ohms à 25°C... essaye, si c'est le 
cas, elle est bonne.